When I was first told this, my initial response was “rubbish“, there was no way that using RAID1 (mirroring) could increase the chance of disk failure, was there?
Then I actually thought about the statement again, and I was wrong!
Consider 2 hard disks A and B. The make/model/manufacturer is irrelevant for this proof.
Given that P(e) is the probability of event e occurring, we can state that:
P(disk A fails) = a
P(disk B fails) = b
Trivially, in a single disk system using either disk A or disk B, the probability of disk failure will be a or b, or for ease of demonstration we shall pick the average of the two.
Therefore, the average chance of a single disk machine suffering disk failure is (a+b)/2.
Now, consider the RAID1 system containing disks A and B.
The chance of a disk failing is the probability of disk A failing or the probability of disk B failing; so:
P(disk A fails or disk B fails) = P(disk A fails) + P(disk B fails) = a + b.
In fact, the chance of disk failure in a RAID1 system doubles. Hardly surprising if you stop and think about it.
Now, the statement I initially inferred actually was: RAID1 increases chances of data loss, which is obviously rubbish, as can be easily shown.
We know the chance of disk failure (and in this case data loss) with a single disk, (a+b)/2.
Now, using RAID1, the chance of data loss is defined as:
The probability of both disk A and disk B failing.
This is defined as:
P(disk A failing and disk B failing) = P(disk A failing) * P(disk B failing) = a * b.
It can be stated that any probability must be in the range 0 <= P(e) <= 1.
For any two numbers i,j; if both i and j satisfy 0 <= i <= 1; 0 <= j <= 1 then:
i * j < i; i * j < j
Therefore, the probability of data loss is lower when using RAID1, however the chance of disk failure doubles!